Back to search

University of Manitoba

Thermal analysis and performance validation for in-vacuum operation of Compton HV-MAPS electron detector for the MOLLER Experiment

Abstract

dc:description.abstract

The Measurement Of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment aims to explore new dynamics beyond the Standard Model. The experiment is placed in Hall A at the Thomas Jefferson National Accelerator Facility (JLab) in Newport News, Virginia, USA. The measurements are acquired by the scattering of longitudinally polarized electrons off un- polarized electrons in a liquid hydrogen target. MOLLER will utilize High Voltage-Monolithic Active Pixel Sensors (HV-MAPS) in the Hall A’s Compton polarimeter to monitor the polariza- tion of the incoming beam from the Continuous Electron Beam Acceleration Facility (CEBAF). The HV-MAPS based electron detector contains a quad-planar geometry and each plane incor- porates three HV-MAPS chips attached. Compton polarimeter utilizes this detector assembly placed inside the vacuum to detect the compton scattered electrons. The chips generate heat during operation, and thus require an effective cooling system in vacuum. The temperature measurement of the HV-MAPS is useful to understand the thermal properties of the pixel de- tector and cooling needs. The present study reviews the efforts towards the cooling strategies, structure modification, and thermal simulations to achieve an in-vacuum operation. Further, the prototyping and successful testing of the electron detector’s cooling system (using a test version of HV-MAPS chips with equivalent heat load) in a local laboratory was performed, and computational fluid dynamics studies are compared with the collected data.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Physics and Astronomy
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shefali, .
Advisor dc:contributor.supervisor
  • Deconinck, Wouter
Committee members dc:contributor.committeemember
  • Gericke, Michael (Physics and Astronomy)
  • Longo. Savino (Physics and Astronomy)

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/39369

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Shefali, .. Thermal analysis and performance validation for in-vacuum operation of Compton HV-MAPS electron detector for the MOLLER Experiment. Master of Science (M.Sc.) thesis, 2025. http://hdl.handle.net/1993/39369