Experimental investigation of combined effects of wildfire smoke and humidity on insulation characteristics of air under ac voltage

Abstract

dc:description.abstract

HVac transmission lines are critical components of power systems and span over various wildfire-prone regions. A major concern during wildfires is smoke, which can travel thousands of kilometers from its source. Wildfire smoke consists of particulate matter and other compounds that can become charged under the strong electric fields near transmission lines and may subsequently influence the insulation characteristics of air. Therefore, investigating the combined effects of wildfire smoke and humidity on the insulation characteristics of air under HVac has become important. This thesis presents an experimental study of the breakdown and partial discharge characteristics of air under varying smoke density and humidity conditions. An experimental test setup consisting of a high voltage circuit and a sealed smoke chamber was developed, where smoke density and humidity levels were controlled and measured. Dielectric breakdown voltage was measured under HVac using a uniform-field sphere-sphere electrode arrangement. The effect of smoke and humidity on breakdown voltage was found to be negligible. Partial discharge characteristics were investigated using a needle-plane electrode arrangement. The partial discharge inception voltage (PDIV) increased with smoke density and increased further under higher humidity, with the PDIV in clean air approximately doubling under combined high smoke and humidity conditions. Phase-resolved partial discharge patterns showed that smoke and humidity suppress negative polarity PD activity at lower voltages. At higher voltages, where both positive and negative polarity PD activity occurs, increased smoke density led to increased PD activity. Partial discharge indicators confirmed these trends, with PD rate, average discharge current, average PD power, and quadratic rate increasing with smoke under these conditions, while higher humidity reduced these values. These behaviors are consistent with increased attachment of negative charge carriers to particulate matter, which suppresses discharge development. However, residual charged smoke particles and space charge from the preceding half cycle can increase PD activity when the applied voltage is sufficiently high. The outcome of this work supports the development of guidelines for the operation of high voltage transmission lines, under varying smoke and humidity conditions.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ekanayaka Arachchige, Anupa Geethanjana Ekanayaka
Advisor dc:contributor.supervisor
  • Kordi, Behzad
Committee members dc:contributor.committeemember
  • Rajapakse, Athula (Electrical and Computer Engineering)
  • Fernando, Namal (Electrical and Computer Engineering)

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/39636

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation