University of Manitoba
Development of a specialized laboratory frost heave testing system to study tangential heave stresses on pile foundations
Abstract
dc:description.abstractThe magnitude and distribution of tangential heave forces on foundations located in frost-susceptible soils in cold regions have received a great deal of attention over the years. A large part of the historically observed variation in measured values, apart from known environmental factors, is attributed to previous misunderstandings regarding the nature of forces and stresses acting along foundations, as well as the measurement methods employed in testing. Despite this, current recommendations offered by engineering guidelines are limited. The development of a specialized laboratory-scale frost heave testing system was pursued in this research study to address the need to better quantify these forces. The novel apparatus sought to improve upon the work of previous researchers who developed their own specialized frost heave testing apparatuses. Essential features of the developed setup included the use of strain gauges to determine the tangential heave stresses acting along the pile shaft, a continuous supply of water at the bottom of the apparatus to promote the formation of ice lenses, temperature sensors to record the temperature profile of the soil and pile with depth, a data acquisition system (DAQ) for automatic data collection, the use of an environmental chamber along with radial insulation to promote one-dimensional frost penetration into the soil, and lastly, a viewing window for visual observation of ice lens formation throughout testing. An instrumented laboratory frost heave test was performed with a synthetic frost-susceptible test soil to verify the design of the experimental test setup. The results from the test largely support the basic functionality of the apparatus based on previous findings from similar studies as well as established theory. Based on the findings of the testing conducted, the developed apparatus, pending minor modifications and optional improvements, can be used for future testing involving remolded soil from the field to determine whether laboratory results can be correlated with those obtained in the field.
Degree
thesis:*- Level thesis:degree_level
- Master of Science (M.Sc.)
- Discipline thesis:degree_discipline
- Civil Engineering
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Soufi, Liam
- Advisors dc:contributor.supervisor
-
- Alfaro, Marolo
- Arenson, Lukas
- Committee members dc:contributor.committeemember
-
- Bartz, Jamie (Civil Engineering)
- Rajapakse, Athula (Electrical and Computer Engineering)
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1993/39953