Abstract

dc:description.abstract

Excess moisture in pavement systems is a major factor contributing to long-term structural deterioration. It can reduce the strength and service life of pavement layers by increasing pore water pressure, weakening the subgrade, and accelerating pavement distresses. Geosynthetics have long been used to improve drainage and reinforcement in roadway applications. Among recent developments, wicking geotextiles have been introduced to enhance moisture removal by transporting water through capillary action in unsaturated soils. However, the effectiveness of the wicking geotextiles in direct contact with soil, particularly under both gravity-driven and capillary-induced drainage conditions, remains insufficiently understood. This study investigates the drainage performance of three geosynthetic systems placed in direct contact with soil: a wicking nonwoven geotextile-geogrid composite, a non-wicking nonwoven geotextile-geogrid composite, and a conventional polypropylene nonwoven geotextile combined with a biaxial geogrid. Laboratory-scale model tests were conducted using a custom-built soil box to evaluate both gravity drainage and capillary-induced drainage setup. Poorly graded sand (SP) was selected for the experiments. Soils were compacted at the optimum moisture content for maximum dry density and instrumented with ECH2O EC-5 soil moisture sensors positioned at multiple locations to continuously monitor volumetric water content throughout the testing period. The drainage performance of the three geosynthetic systems was compared with untreated soil under identical testing conditions. The laboratory results demonstrated that all geosynthetic systems enhanced moisture removal compared with natural gravity drainage setup. Among the investigated materials, the wicking geotextile exhibited the greatest overall drainage performance under gravity drainage setup conditions. In contrast, the capillary-induced drainage tests showed only limited moisture redistribution for all three geosynthetic systems, which indicates that capillary transport alone was insufficient to produce significant desaturation under the laboratory conditions considered. A small, localized response was observed near the soil surface and over a short lateral distance in the WickGrid™ system. In both drainage tests, moisture removal was faster and more pronounced closer to the outlet. The findings of this research improve the understanding of moisture movement in soil-geosynthetics systems. The study also establishes a laboratory methodology for assessing geosynthetic drainage behaviour and contributes to the moisture management development strategies for transportation infrastructure.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Civil Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hassan, Md. Zahid
Advisors dc:contributor.supervisor
  • Bartz, Jamie
  • Alfaro, Marolo
Committee members dc:contributor.committeemember
  • Blatz, James (Civil Engineering)
  • Mantilla, Ricardo (Civil Engineering)

Subjects

dc:subject × 4

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/40195

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hassan, Md. Zahid. Evaluating the drainage performance of a wicking nonwoven geotextile-geogrid composite using a custom-built laboratory device. Master of Science (M.Sc.) thesis, 2026. http://hdl.handle.net/1993/40195