Back to search

Journal of X-ray Science and Technology, IOS Press

The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation

Abstract

dc:description.abstract

Breast CT is a promising modality whose inherent scatter could be used to reconstruct electron density (rho_e) images. This has led us to investigate the benefits of reconstructing linear attenuation coefficient (mu) and (rho_e) images of the breast. First generation CT provides a cost-effective and simple approach to reconstruct (rho_e) images in a laboratory but is limited by the anisotropic probability of scatter, attenuation, noise and contaminating scatter (coherent and multiple scatter). These issues were investigated using Monte Carlo (MC) simulations of a first generation breast scatter enhanced CT (B-SECT) system. A reconstruction algorithm was developed for the B-SECT system and is based on a ring of detectors which eliminates the scatter dependence on the relative position of the scattering centre. The algorithm incorporates an attenuation correction based on the (mu) image and was tested against analytical and MC simulations. MC simulations were also used to quantify the dose per scan. The ring measures a fraction of the total single incoherent scatter which is proportional to ray integrals of (rho_e) and can be quantified even when electron binding is non negligible. The algorithm typically reconstructs accurate (rho_e) images using a single correction for attenuation but has the capability for multiple iterations if required. MC simulations show that the dose coefficients are similar to those of cone beam breast CT. Coherent and multiple scatter can not be directly related to (rho_e) and lead to capping artifacts and overestimated (rho_e) by a factor greater than 2. This issue can be addressed using empirical corrections based on the radiological path of the incident beam and result in (rho_e) images of breast soft tissue with 1% accuracy, 3% precision and a mean glandular dose of 4 mGy for a 3D scan. The reconstructed (rho_e) image was more accurate than the (rho_e) estimate derived from the (mu) image. An alternative correction based on the thickness of breast traversed by the beam provides an enhanced contrast image reflecting the breast scatter properties. These results demonstrate the feasibility of detecting small (rho_e) changes in the intact breast and shows that further experimental evaluation of this technique is warranted.

Degree

thesis:*
Level thesis:degree_level
Doctor of Philosophy (Ph.D.)
Discipline thesis:degree_discipline
Physics and Astronomy
Grantor dc:publisher
Journal of X-ray Science and Technology, IOS Press
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alpuche Aviles, Jorge Edmundo
Advisor dc:contributor.supervisor
  • Pistorius, Stephen (Physics & Astronomy)
Committee members dc:contributor.committeemember
  • Elbakri, Idris (Physics and Astronomy)
  • Fiege, Jason (Physics and Astronomy)
  • Sherif, Sherif S. (Electrical and Computer Engineering)
  • Chapman, Dean (College of Medicine-Anatomy & Cell Biology, University of Saskatchewan)

Subjects

dc:subject × 6

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
J.E. Alpuche Aviles, S. Pistorius, R. Gordon and I.A. Elbakri, A novel hybrid reconstruction algorithm for first generation incoherent scatter CT (ISCT) of large objects with potential medical imaging applications. J Xray Sci Technol, 2011. 19(1): p. 35-56.
J.E. Alpuche Aviles, S. Pistorius, I.A. Elbakri, R. Gordon and B. Ahmad, A 1st generation scatter CT algorithm for electron density breast imaging which accounts for bound incoherent, coherent and multiple scatter: A Monte Carlo study . J Xray Sci Technol, 2011. 19(4): p. 477-499.

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Alpuche Aviles, Jorge Edmundo. The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation. Doctor of Philosophy (Ph.D.) thesis, Journal of X-ray Science and Technology, IOS Press, 2011. http://hdl.handle.net/1993/4970