Back to search

Digital Repository at the University of Maryland

Green Facade Energetics

Abstract

dc:description.abstract

Rising energy costs and a warming climate create the need for innovative, low-carbon technologies that help cool buildings. We constructed four small buildings and instrumented them to measure the cooling effect of a green façade on their south and west walls. The green façade significantly reduced the temperature of the building's ambient air, exterior surface, and interior air, and the heat flux through the vegetated wall. Using a mathematical model, we determined that the whole-building cooling load reduction (1.4 to 28.4%) depended on building construction, green façade placement, and especially whether the windows were covered. An emergy analysis of a south-facing green façade revealed that the total emergy consumed could be balanced by the electricity saved from reduced air conditioning if the cooling load was reduced by at least 14%. With thoughtful design and placement of a green façade it can sustainably and effectively help cool buildings.

Degree

thesis:*
Department dc:contributor.department
Biological Resources Engineering
Grantor dc:publisher
Digital Repository at the University of Maryland
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Price, Jeffrey
Advisor dc:contributor.advisor
  • Tilley, David R

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1903/11291

Chain of custody

source
Harvested from
University of Maryland
Base URL
api.drum.lib.umd.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Price, Jeffrey. Green Facade Energetics. Digital Repository at the University of Maryland, 2010. http://hdl.handle.net/1903/11291