Measurements of Soot Temperature in a Diffusion Flame Using a Digital Camera
Abstract
dc:description.abstractTemperatures were measured in a laminar axisymmetric diffusion flame with a digital camera. The camera was a Nikon D700, modified to remove the Infra-Red (IR) cut filter and the anti-aliasing filter. Temperatures were obtained using ratio pyrometry at 550, 650, and 900 nm following deconvolution. The camera was calibrated with a blackbody furnace. Measurements were made for an 88 mm high laminar ethylene/air diffusion flame in co-flow on a burner with an 11.1 mm inside diameter. Soot temperatures were measured in the range of 1250 - 2000 K with an estimated uncertainty of ±60 K. The diagnostic requires axisymmetric, optically thin flames, and regions with temperatures greater than 1250 K and soot volume fractions greater than 0.1 ppm. The results agreed with published measurements for this flame. The new diagnostics provide a convenient and economical way to perform these measurements with good accuracy and spatial resolution.
Degree
thesis:*- Department dc:contributor.department
- Fire Protection Engineering
- Grantor dc:publisher
- Digital Repository at the University of Maryland
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Castillo Moreno, Jose A.
- Advisor dc:contributor.advisor
-
- Sunderland, Peter B.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1903/12807