Back to search

Digital Repository at the University of Maryland

An Experimental Analysis of Firefighter Protective Clothing: The Influences of Moisture and a Thermally Activated Expanding Air-Gap

Abstract

dc:description.abstract

Thermally protective clothing garments are necessary pieces of equipment that ensure the life safety of firefighters. In this analysis, material samples of such garments are tested experimentally with and without the presence of both moisture and a thermally activated, expanding air-gap. Moisture is delivered to samples via a porous baseplate with an integral fluid supply system, simulating perspiration. Operation of the expanding air-gap is controlled by a custom-designed assembly of shape-memory rings, which undergo a shape transformation over a predetermined temperature range. Samples with varying characteristic layers and arrangements are subjected to a controlled thermal exposure. The performances of tested samples are evaluated based on normalized temperature parameters. Assembly characteristics offering the greatest protective performance are then established. Results suggest that limiting moisture absorption in the thermal liner of a garment and implementing air-gaps of increasing thickness improve the protective performance of firefighter protective clothing.

Degree

thesis:*
Department dc:contributor.department
Fire Protection Engineering
Grantor dc:publisher
Digital Repository at the University of Maryland
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • White, James Patrick
Advisor dc:contributor.advisor
  • di Marzo, Marino

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1903/12818

Chain of custody

source
Harvested from
University of Maryland
Base URL
api.drum.lib.umd.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

White, James Patrick. An Experimental Analysis of Firefighter Protective Clothing: The Influences of Moisture and a Thermally Activated Expanding Air-Gap. Digital Repository at the University of Maryland, 2012. http://hdl.handle.net/1903/12818