Back to search

Digital Repository at the University of Maryland

EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF PLANAR ION DRAG MICROPUMP GEOMETRICAL DESIGN PARAMETERS

Abstract

dc:description.abstract

To deal with increasing heat fluxes in electronic devices and sensors, innovative new thermal management systems are needed. Proper cooling is essential to increasing reliability, operating speeds, and signal-to-noise ratio. This can be achieved only with precise spatial and temporal temperature control. In addition, miniaturization of electric circuits in sensors and detectors limits the size of the associated cooling systems, thereby posing an added challenge. An innovative answer to the problem is to employ an electrohydrodynamic (EHD) pumping mechanism to remove heat from precise locations in a strictly controlled fashion. This can potentially be achieved by micro-cooling loops with micro-EHD pumps. Such pumps are easily manufactured using conventional microfabrication batch technologies. The present work investigates ion drag pumping for applications in reliable and cost effective EHD micropumps for spot cooling. The study examines the development, fabrication, and operation of micropumps under static and dynamic conditions. An optimization study is performed using the experimental data from the micropump prototype tests, and a numerical model is built using finite element methods. Many factors were involved in the optimization of the micropump design. A thorough analysis was performed of the major performance-controlling variables: electrode and inter-electrode pair spacing, electrode thickness and shape, and flow channel height. Electrode spacing was varied from 10 µm to 200 µm and channel heights from 50 µm to 500 µm. Also, degradation of the electrodes under the influence of an intense electric field was addressed. This design factor, though important in the reliability of EHD micropumps, has received little attention in the scientific and industrial applications literature. Experimental tests were conducted with prototype micropumps using the electronic liquid HFE7100 (3M®). Flow rates of up to 15 ml/min under 15 mW power consumption and static pumping heads up to 750 Pa were achieved. Such performance values are acceptable for some electronic cooling applications, where small but precise temperature gradients are required.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Digital Repository at the University of Maryland
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Benetis, Vytenis
Advisors dc:contributor.advisor
  • Ohadi, Michael
  • Smela, Elisabeth

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1903/2671

Chain of custody

source
Harvested from
University of Maryland
Base URL
api.drum.lib.umd.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Benetis, Vytenis. EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF PLANAR ION DRAG MICROPUMP GEOMETRICAL DESIGN PARAMETERS. Digital Repository at the University of Maryland, 2005. http://hdl.handle.net/1903/2671