Back to search

Digital Repository at the University of Maryland

Numerical modeling of full scale limited ventilation fire tests

Abstract

dc:description.abstract

Underventilated enclosure fires represent one of the largest causes of fire fatalities and understanding their behavior is of great interest. The newest major release of the Fire Dynamics Simulator (FDS) has made significant progress towards providing a tool for accurate modeling of underventilated fire behavior. This study sought to evaluate the effectiveness of the extinction model and two-step combustion model in FDS version 5 by simulating full scale fire tests in an apartment setting with realistic furniture items using heat release rate data from furniture calorimeter and load cell. The extinction model provides a more accurate representation of the fire behavior in the compartment but the oxygen and temperature results are not satisfactory for severely underventilated fires. The effects of the enclosure causes heat release rate data from free-burn calorimeter tests to give a poor representation of the burning behavior of real furniture items in a compartment.

Degree

thesis:*
Department dc:contributor.department
Fire Protection Engineering
Grantor dc:publisher
Digital Repository at the University of Maryland
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Boehmer, Haavard
Advisor dc:contributor.advisor
  • Trouvé, Arnaud

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1903/8978

Chain of custody

source
Harvested from
University of Maryland
Base URL
api.drum.lib.umd.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Boehmer, Haavard. Numerical modeling of full scale limited ventilation fire tests. Digital Repository at the University of Maryland, 2008. http://hdl.handle.net/1903/8978