Experimental Evaluation of Stability with the Aerrow Graphite Calorimetry System
Abstract
dc:description.abstractThis work aims to experimentally determine the properties of the Aerrow calorimetrysystem for clinical reference dosimetry. Calorimetric radiation dosimetry measures the thermalenergy dissipation of radiation in an absorbing medium, typically water or graphite, tocalculate the absorbed dose output from a radiation source. Two prototype Aerrow deviceswere compared in high-energy photon beams and administered by a Varian TrueBeam linearaccelerator in a water-equivalent solid phantom. The phantom was chosen as close to a clinicaluse scenario and was not thermally controlled. For eight months, an Exradin®A1SLfarmer-type ionization chamber acted as a reference dosimeter for the Aerrow calorimetrysystem. The precision and accuracy of the Aerrow probes were compared favourably to theion chamber as a gold standard dose measurement using both devices. The Aerrow MK5prototype, or standard format Aerrow, was found to have a standard deviation of the response(across eight months) of 0.4% throughout eight experiments, n = (5−10) runs. TheAerrow MK7, or Aerrow mini, was examined similarly and was found to have a stability(standard deviation) of 0.7% while following the initial dose-rate analysis. The dose-to-graphiteto dose-to-water conversion was validated with a water equivalent solid phantomusing EGSnrc. The conversion factor in a water phantom agreed to within 0.5% between thesolid water phantom results for all photon beam qualities and across both Aerrow probes.Heat transfer correction factors were estimated using COMSOL Multiphysics®finite elementanalysis (FEA) software. However, agreement of the beam-on and post-drift portions of thesimulated signal was not achieved, so the results have been presented without heat transfercorrections considered. This work shows a significant disagreement between the ionizationchamber collected data and the Aerrow MK7 operated in quasi-adiabatic mode and suggeststhat the heat transfer effects are too substantial for clinical use in this mode
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Grantor dc:publisher
- McGill University
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- MacKay, Norman
- Advisors dc:contributor.advisor
-
- Renaud, James (Supervisor2)
- Seuntjens, Jan (Supervisor1)
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- All items in eScholarship@McGill are protected by copyright with all rights reserved unless otherwise indicated.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- OCLC
- 1428737353
- Identifier URI
- https://hdl.handle.net/20.500.14905/106942
- Dc Identifier Other
- hyrax:ft848w54j