Back to search

McGill University

Experimental Evaluation of Stability with the Aerrow Graphite Calorimetry System

Abstract

dc:description.abstract

This work aims to experimentally determine the properties of the Aerrow calorimetrysystem for clinical reference dosimetry. Calorimetric radiation dosimetry measures the thermalenergy dissipation of radiation in an absorbing medium, typically water or graphite, tocalculate the absorbed dose output from a radiation source. Two prototype Aerrow deviceswere compared in high-energy photon beams and administered by a Varian TrueBeam linearaccelerator in a water-equivalent solid phantom. The phantom was chosen as close to a clinicaluse scenario and was not thermally controlled. For eight months, an Exradin®A1SLfarmer-type ionization chamber acted as a reference dosimeter for the Aerrow calorimetrysystem. The precision and accuracy of the Aerrow probes were compared favourably to theion chamber as a gold standard dose measurement using both devices. The Aerrow MK5prototype, or standard format Aerrow, was found to have a standard deviation of the response(across eight months) of 0.4% throughout eight experiments, n = (5−10) runs. TheAerrow MK7, or Aerrow mini, was examined similarly and was found to have a stability(standard deviation) of 0.7% while following the initial dose-rate analysis. The dose-to-graphiteto dose-to-water conversion was validated with a water equivalent solid phantomusing EGSnrc. The conversion factor in a water phantom agreed to within 0.5% between thesolid water phantom results for all photon beam qualities and across both Aerrow probes.Heat transfer correction factors were estimated using COMSOL Multiphysics®finite elementanalysis (FEA) software. However, agreement of the beam-on and post-drift portions of thesimulated signal was not achieved, so the results have been presented without heat transfercorrections considered. This work shows a significant disagreement between the ionizationchamber collected data and the Aerrow MK7 operated in quasi-adiabatic mode and suggeststhat the heat transfer effects are too substantial for clinical use in this mode

Degree

thesis:*
Name thesis:degree_name
Master of Science
Grantor dc:publisher
McGill University
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • MacKay, Norman
Advisors dc:contributor.advisor
  • Renaud, James (Supervisor2)
  • Seuntjens, Jan (Supervisor1)

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • All items in eScholarship@McGill are protected by copyright with all rights reserved unless otherwise indicated.
Language dc:language.iso
en

Identifiers

dc:identifier.*
OCLC
1428737353
Dc Identifier Other
hyrax:ft848w54j

Chain of custody

source
Harvested from
McGill University
Base URL
mcgill.scholaris.ca/server/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

MacKay, Norman. Experimental Evaluation of Stability with the Aerrow Graphite Calorimetry System. McGill University, 2023. https://doi.org/10.82308/30938