Abstract
dc:description.abstractBackground Bone graft procedures are commonly performed worldwide for segmental bone defects resulting from high-energy trauma, congenital deformity, infection or tumor resection. The current gold standard for repair of large long bone defects is the use of bone and blood vessels, as vascularized bone graft, harvested from another part of the body and transplanted to the area of the missing tissue. This creates significant donor site injury and is often an inadequate anatomical match. Making synthetic vascularized bone without recourse to potentially dangerous and expensive growth factors can potentially revolutionize reconstructive surgery and provide significant improvements in patients' lives. Inducing new blood vessels and engineering bones to custom geometry is the objective of many researchers but several technological hurdles remain. My thesis explores whether axial vascularization of a bioceramic affects bone generation from marrow aspirate and, to understand the impact of axial vascularization in bio-scaffolds. Methods We designed, cross-shaped, monetite bioceramic to fit the rat femoral vein and impregnated the scaffold with autologous bone marrow taken from the other leg. This implant was then implanted circumferentially around the vein of 16 rats and removed after 8 weeks. The structure, stability, and composition of the new bone was be assessed by micro computed tomography (micro-CT), Scanning Electron Microscope (SEM), and histopathology examinations. Results Scaffolds were printed with a mean deviation of +150 µm compared to their theoretical CAD model, were mainly composed of monetite (80.2%wt) and unreacted α- (1.8 %wt) and β-TCP (18 %wt) phases and displayed a micro- (> 50%vol between 1 and 10 µm) and Nano-porosity. A greater volume of new bone tissue was observed and quantified (SEM, µCT) in scaffolds perfused by a central vein compared with the non-perfused negative control (65.0 ± 5.6 % of the initial scaffold volume versus 29.0 ± 4.2%, P < 0.0001, N=4 or 5, triplicate representative areas per sample). Bone formation and ceramic biodegradation were (2.2 ± 0.2) and (2.9 ± 0.3) times higher for the experimental group than for the control one, respectively. In addition, implant biodegradation for both control and experimental groups were far greater than for both historical controls (implant and implant vascularized by a vein, ≈ 16.5% degradation). Conclusion Experiments showed promising results, we produced an axially vascularized tissue-engineered bone using marrow at a higher level than has been reported in the literature. This illustrates the intimate relationship between angiogenesis and osteogenesis, this is especially important to tackle the issues encountered for regeneration of critical-sized bone defects. In this study we showed that the presence of a vein perfusing a blood marrow soaked monetite implant allowed for generating enormous amount of bone (up to 65%) replacing the quasi totality of the implant (≈ 15% remaining). Even more, the structure adopted by this host-made engineered construct may surprisingly remain the structure of long bone, including a low vascularized and dense cortical layer surrounding a highly vascularized trabecular zone which hosts the marrow. Future work will focus on the mechanical stability of these vascularized bone flaps in load bearing sites.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Grantor dc:publisher
- McGill University
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Baradaran, Aslan
- Advisor dc:contributor.advisor
-
- Barralet, Jake (Internal/Supervisor)
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- All items in eScholarship@McGill are protected by copyright with all rights reserved unless otherwise indicated.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- OCLC
- 1117498251
- Identifier URI
- https://hdl.handle.net/20.500.14905/127361
- Dc Identifier Other
- hyrax:vx021h39g