Back to search

McMaster University

Dynamic and Steady State Behaviour of an Extractive Distillation Column

Abstract

dc:description.abstract

<p>This project was the second part of a long-term study into the control of an extractive distillation unit. A fifteen stage extractive distillation column was re-built and operated over a range of operating levels. Overhead product acetone composition was limited to approximately 0.94 mole fraction acetone due to tray liquid priming. A steady state simulation was developed to aid in a better understanding of the process. Murphree vapour tray efficiencies were adjusted within the simulation to match experimental and simulated product composition results. The simulation was used to accurately predict unfitted experimental results. Dynamic behaviour of the column was studied by relating product composition responses to changes in disturbance and manipulated variables. Dynamic behaviour was analysed by frequency response and real time response fitting. Experimental data was relatively noisy. First order transfer function models with dead time, fitted in the real time domain, were satisfactory.</p>

Degree

thesis:*
Department dc:contributor.department
Chemical Engineering
Year dc:date.issued
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • O`Neill, Dwayne L.
Advisor dc:contributor.advisor
  • Wright, J.D.

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Dc Identifier Other
opendissertations/508
1106
874667

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

O`Neill, Dwayne L.. Dynamic and Steady State Behaviour of an Extractive Distillation Column. 1975. http://hdl.handle.net/11375/10010