McMaster University
Nitrogen Implanted α-SiC : A Correlation Between Electrical (C-V) Measurements and Damage Studies Using the Channeling Technique.
Abstract
dc:description.abstract<p>The annealing behaviour of 15N implanted, aluminum doped-SiC has been studied by measuring the differential capacitance as a function of applied bias. The samples were doubly implanted at 450°c with 45 Kev and 25 Kev ions, for a dose of 10^16/cm^2 at each energy.</p> <p> An n-i-p structure with a thick insulator region was found after annealing at 1000°c. The thickness of this i region could be substantially reduced with additional annealing at higher temperatures, and a fairly good n-p junction was obtained after 1480°c anneal.</p> <p> About 20-30% of the implanted nitrogen ions were found to be electrically active.</p> <p> The C-V behaviour was found to have large variations with the a.c. measuring frequency.</p>
Degree
thesis:*- Department dc:contributor.department
- Engineering Physics
- Year dc:date.issued
- 1975
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chan, Albert M. C.
- Advisor dc:contributor.advisor
-
- Thompson, D.A.
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/12406