Back to search

McMaster University

FEASIBILITY OF MEASURING SELENIUM IN HUMANS USING IN VIVO NEUTRON ACTIVATION ANALYSIS

Abstract

dc:description.abstract

Selenium (Se), an essential trace element, plays an important role in the normal function of a number of Se-dependent biological processes. Many studies have demonstrated that selenium deficiency in the body may contribute to an increased risk for certain neoplastic diseases (including colonic carcinoma, gastric carcinoma, pulmonary carcinoma and prostate carcinoma), as well as diseases of the cardiovascular, osseous, nervous systems and retardation of bone formation. However, at higher concentrations Se is cytotoxic. For these reasons it is desirable to have a means of monitoring selenium concentration in humans. The feasibility of measuring selenium in humans using the in vivo neutron activation analysis (IVNAA) technique was studied. For this purpose human hand tissue equivalent phantoms were prepared with varying amounts of selenium and irradiated by a low energy neutron beam produced by the 7Li(p,n)7Be reaction by employing the high beam current Tandetron accelerator. The counting data saved using the 4π NaI(TI) detection system in anticoincidence, coincidence and singles modes of detection were analyzed. The selenium was detected via the neutron capture reaction, 76Se(n,γ)77mSe, whereas calcium was detected through the 48Ca(n,γ)49Ca reaction. The peak areas of Se and Ca were computed and the Se concentrations were normalized to the Ca concentrations for various time segments of detection. The calibration lines were drawn between Se/Ca concentration and Se/Ca counts ratio. The minimum detection limits (MDL) were obtained and the inverse variance weighted mean value of MDL was finally calculated for three time segments. During the analysis of counting data it was also found that 18O is activated in water phantoms and becomes short lived radioactive 19O having T1/2=26.9 s. To the author’s best knowledge, this study for the first time presents the MDL value in terms of Se/Ca concentration for the human hand bone equivalent phantom obtained from in vivo neutron activation analysis and these results will provide a good basis for future investigations.

Degree

thesis:*
Department dc:contributor.department
Medical Physics
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Syed, Nasir Ahmed Tahir
Advisor dc:contributor.advisor
  • Chettle, David R.

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Syed, Nasir Ahmed Tahir. FEASIBILITY OF MEASURING SELENIUM IN HUMANS USING IN VIVO NEUTRON ACTIVATION ANALYSIS. 2015. http://hdl.handle.net/11375/17191