The Design and Construction of a Surface Analysis Station (Part A)
Abstract
dc:description.abstract<p> The design, construction, and initial operation of a surface analysis station were undertaken. The final UHV system is equipped for ion surface scattering, low energy electron diffraction, Auger analysis, secondary ion mass spectroscopy and residual gas analysis. </p> <p> The main goal of this project was the preliminary operation of the ion surface scattering equipment. A complete beam transport system was constructed utilizing an Einzel lens and electrostatic quadroles. </p> <p> The ion surface scattering was effected through the use of a time-of-flight (TOF) technique to obtain an energy spectrum of particles backscattered from a target surface. The TOF spectrum and subsequent energy spectrum were for 5.1 keV hydrogen ions incident on a practical silver target. </p>
Degree
thesis:*- Department dc:contributor.department
- Engineering Physics
- Year dc:date.issued
- 1979
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Cuthbert, John Richard
- Advisor dc:contributor.advisor
-
- Robinson, J.E.
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/22391