<p> Levitation melting was used to measure the equilibrium between H2-H2o or CO-C02 gas mixtures and pure Fe or Fe-Cr alloys over the temperature range 1550 - 1750°C. The effects of thermal diffusion on the two types of gases were investigated. First and second order interaction parameters were employed to describe the interaction between oxygen and chromium {up to 25 wt. pct. of Cr.). </p>

Degree

thesis:*
Department dc:contributor.department
Metallurgy
Year dc:date.issued
1968

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Larché, Francis C. L.
Advisor dc:contributor.advisor
  • McLean, A.

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Larché, Francis C. L.. Oxygen Solubility in Liquid Iron and Iron-Chromium Alloys. 1968. http://hdl.handle.net/11375/18485