Back to search

McMaster University

The Transient Behavior of an Ethane Dehydrogenation Furnace

Abstract

dc:description.abstract

This report deals with the mathematical model of the transient behaviour of an existing ethane dehydrogenation furnace which is composed of two main sections: a preheating convection section and a radiant-heated section. The correlation of pressure drop with time has been found from the available data. The fractional carbon deposition and the multiplier coefficient of a pressure drop equation have been determined by the direct search optimization technique of Hooke and Jeeves. An optimal policy for the cyclic operation of the furnace was determined by considering plant temperature profile and hydrocarbon/ steam ration as parameters for maximizing average ethylene produced per day. The effect of temperature profile on the distribution of carbon deposited along the reactor was also predicted and discussed.

Degree

thesis:*
Department dc:contributor.department
Chemical Engineering
Year dc:date.issued
1967

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Li, Mou-Ching
Advisor dc:contributor.advisor
  • Johnson, A. I.

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Li, Mou-Ching. The Transient Behavior of an Ethane Dehydrogenation Furnace. 1967. http://hdl.handle.net/11375/18597