Back to search

McMaster University

Reactivity Meter Analysis of Rod-Drop Experiments in Zed-2

Abstract

dc:description.abstract

<p> A reactivity meter code based on point kinetics was developed. Rod-drop experiments performed in the ZED-2 reactor tested the code for various detector and rod-drop positions. A delayed neutron hold-up effect was observed whenever a rod was dropped close to a detector. A better understanding of this effect was obtained through a theoretical analysis of the pertinent experiments. The three-dimensional kinetics code, CERBERUS, was used for the theoretical analysis. </p>

Degree

thesis:*
Department dc:contributor.department
Engineering Physics
Year dc:date.issued
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moniz, Manuel
Advisor dc:contributor.advisor
  • Jones, R.T.

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Moniz, Manuel. Reactivity Meter Analysis of Rod-Drop Experiments in Zed-2. 1975. http://hdl.handle.net/11375/19795