Back to search

McMaster University

INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS

Abstract

dc:description.abstract

The wide band gap semiconductor Cadmium Zinc Telluride (CZT) is of recent interest for medical imaging at room temperature. A number of properties, including superior energy resolution, 3D photon position sensitivity, compact size, direct photon conversion and energy-resolving capability, make CZT a promising candidate for positron emission tomography (PET) and photon-counting X-ray imaging systems. Despite these advantages, drawbacks, such as low mobility of holes, hole trapping, charge sharing effect and characteristic X-ray escape degrade the performance of large volume CZT detectors. In this research, characterization and evaluation of single-crystal CZT photon detector using simulation and experimental studies were done. First, a comprehensive analytical model was developed and implemented by using Monte Carlo simulation and finite element analyses. This model includes the generation and transportation of charge carries within CZT detectors, and it provides useful guidance in optimizing the electrode design and associated readout circuits. Second, the performance of a 20×20×5mm3 CZT crystal with 8×8 pixel anodes and a planar cathode was integrated with readout electronics that can be used to build a PET system was studied. The experiments demonstrate an energy resolution of ~2.26±0.84% full width half maximum (FWHM) at 662 keV and 19±3 ns coincidence time resolution with planar parallel field configuration. A novel algorithm based on charge sharing effect and transient signal analysis targeting the improvement of spatial resolution, was proposed. The sub-pitch spatial resolution is found to be ~30 µm and ~250 µm under signal-to-noise ratio of ~17, for inside and outside the valid range of charge sharing, respectively. Finally, the feasibility of CZT in photon-counting Computed Tomography (CT) was studied by using monoenergetic sources, with a special attention paid to energy degradation due to characteristic X-ray escape and the charge sharing effect. The effects of detector configuration and incident beam location were also investigated. The results show that the pixel size can be reduced to 500 µm without significant count loss (~5%) and charge loss (~15%) for the photo-counting X-ray applications.

Degree

thesis:*
Department dc:contributor.department
Electrical and Computer Engineering
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zheng, Xiaoqing
Advisor dc:contributor.advisor
  • Deen, M. Jamal

Subjects

dc:subject × 2

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Zheng, Xiaoqing. INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS. 2017. http://hdl.handle.net/11375/23880