Back to search

McMaster University

A Comparison of Beam Induced Damage from Xenon and Gallium Focused Ion Beams

Abstract

dc:description.abstract

Focused ion beam/scanning electron microscopy (FIB/SEM) is a tool commonly used for applications including preparation of site-specific transmission electron microscopy (TEM) samples, nanotomography, and electronic circuit edit. Another potential application is optical device prototyping; however, the ion beam itself has been shown to cause damage fatal to device operation. This thesis first includes several examples of FIB-fabricated optical devices that had limited functionality compared to simulation. Second, the underlying causes of ion beam-induced optical damage from gallium and xenon ion sources is characterized. Monte Carlo simulations of ion-solid interactions were confirmed using TEM analysis to measure the thickness of the damaged layer. For crystalline samples such as silicon, Raman response can be used as a measure of lattice damage. Using these techniques, it was found that optical damage from a gallium beam is more severe than from a xenon beam, and occurs in the form of lattice amorphization and implantation of beam ions. This damage hinders optical coupling by altering the physical and electronic structure of the sample. Consequently, the xenon PFIB is a better choice for optical device prototyping.

Degree

thesis:*
Department dc:contributor.department
Materials Science and Engineering
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Norris, Samuel
Advisor dc:contributor.advisor
  • Bassim, Nabil

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Norris, Samuel. A Comparison of Beam Induced Damage from Xenon and Gallium Focused Ion Beams. 2019. http://hdl.handle.net/11375/24675