Back to search

McMaster University

Detection of Gadolinium in Liver and Kidney Phantoms Using X-Ray Fluorescence

Abstract

dc:description.abstract

Gadolinium (Gd) is commonly used in contrast agents (GBCAs) to improve magnetic resonance imaging. GBCAs improve tumor imaging and were thought to be stable and clear from the body through excretion after administration. However, they have been found to dissociate and remain in organs such as the liver and kidneys. In these studies, a non-invasive Cd-109 based K x-ray fluorescence (K-XRF) “Clover-Leaf” detection system to study liver and kidney Gd levels was investigated to improve the minimum detection limit (MDL). Two Cd-109 sources, one with a relatively low activity of 0.78 GBq and a second high activity source of 5 GBq irradiated a human torso water phantom containing liver and kidney phantoms with Gd concentrations ranging from 0-100 ppm. The MDL was calculated from two different time measurements 5 hours (weak source) and 30 minutes (strong source). In addition, liver and kidney phantom measurements with overlaying tissue thicknesses from 6-26 mm were investigated. At present, the K-XRF detection system is able to detect the Gd in each phantom with both sources. The MDL for the liver and kidney with the weaker source is 2.95 ppm and 3.60 ppm, respectively. The MDL for the stronger source is 3.61 ppm and 3.87 ppm, respectively. The overlaying tissue thickness MDLs decreased exponentially since the thickness increased which increases the scattering and attenuation. Simulations with MCNP successfully modelled the experiments. MCNP simulations of the kidney with varying Gd concentrations in the cortex and medulla suggest that the XRF measurement is not sensitive to the Gd distribution in the phantom. To conclude, this detection system can measure Gd in liver and kidney phantoms and has low MDLs. Future work should focus on varying the detection capabilities, measuring the effects to the organs at risk, possible clinical trials, and improving the MCNP model and peak extraction.

Degree

thesis:*
Department dc:contributor.department
Radiation Sciences (Medical Physics/Radiation Biology)
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cyr, Mélodie
Advisors dc:contributor.advisor
  • Chettle, Dr. David
  • McNeill, Dr. Fiona

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Cyr, Mélodie. Detection of Gadolinium in Liver and Kidney Phantoms Using X-Ray Fluorescence. 2020. http://hdl.handle.net/11375/25894