Abstract
dc:description.abstractThe work described in this dissertation focuses on developing simple yet effective assays integrating nucleic acid (NA) aptamers with rolling circle amplification (RCA) for the detection of non-NA biomarkers. The first project, a comprehensive literature review, highlights the current state of the art in functional NA-based RCA applications, and identifies shortcomings in the detection of non-NA targets with RCA. Biosensor design is critically evaluated from four key perspectives: regulation, efficiency, and detection of RCA, and the integration of all three components for point of care (POC) applications. The second project investigates how target-binding to a linear aptamer can be utilized to regulate RCA in a simple and inexpensive format. Phi29 DNA polymerase (DP) exhibits difficulty processing DNA strands that are bound to non-NA materials such as proteins. The work uses this restriction of phi29 DP as a feature by utilizing protein-binding aptamers as primer strands (aptaprimers) for RCA. The simplicity is showcased by adapting the method to a cellulose paper-based device for the real-time detection and quantification of PDGF or thrombin within minutes. As the second project is a turn-off sensor, the third project exploits the inherent 3’-exonuclease activity of phi29 DP to generate a simple turn-on assay instead. As target-bound aptamers were shown to be resistant to exonuclease activity, the phi29 DP preferentially digests target-free aptaprimers instead of target-bound aptaprimers. The target-bound aptaprimer could be liberated by a circular template (CT) by incorporating toehold-mediated strand displacement (TMSD), and used for RCA. Sensitivity was improved relative to project two, though the dynamic range was narrow owing to difficulty liberating target-bound aptaprimer at high target concentrations. Project four instead used RecJ, which has 5’-exonuclease activity, to modulate aptaprimer availability. Similarly to project three, target-binding conferred protection on the aptaprimer from 5’-exonuclease digestion by RecJ. By including a free 3’ terminus on the aptaprimer, inhibition of RCA due to target binding was avoided and CT-mediated TMSD was not needed, simplifying the assay. As well, this approach was generalizable as it was demonstrated using both a protein (thrombin) and a small molecule (ochratoxin A) target. This turn-on method further improved the assay compared to project three with a 100-fold enhancement in sensitivity and a restoration of the dynamic range. In sum, this work contributed multiple simple and sensitive approaches for the real-time fluorescent detection of proteins and small molecules with the RCA of linear aptamers.
Degree
thesis:*- Department dc:contributor.department
- Chemistry and Chemical Biology
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bialy, Roger
- Advisors dc:contributor.advisor
-
- Brennan, John
- Li, Yingfu
- Filipe, Carlos
Subjects
dc:subject × 18Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/18991