Back to search

McMaster University

Application of Atmospheric Pressure Chemical Ionization Gas Chromatography in Urine Organic Acid Analysis

Abstract

dc:description.abstract

Inborn errors of metabolism (IEM) cause significant morbidity and mortality when left untreated. Urine organic acid (UOA) analysis is often a first-line investigation when an IEM is suspected. UOAs are usually qualitatively analyzed via the current gold standard, GC-EI-MS (Gas Chromatography-Electron Impact-Mass Spectroscopy). The Agilent 7890 GC in tandem with the Waters’ Xevo TQ-S MS contains an easily interchangeable LC-ESI (liquid chromatography-electrospray Ionization) and GC-APCI (Atmospheric Pressure Chemical Ionization) instrument set-up, while maintaining accuracy and sensitivity in both LC and GC applications. Utilizing this novel GC-APCI instrument, this project aims to develop and validate a new UOA method for clinical use. Furthermore, utilizing the machine’s MRM mode would increase sensitivities thus allowing for hopefully quantitative analysis. Chemical standards and patient urine samples were extracted via a liquid-liquid ether extraction and derivatized with BSTFA for proper GC elution. Results were compared on the current gold standard GC-EI-MS instrument and the new GC-APCI-MS instrument. Initial instrument suitability and method setup was then optimized. Source moisture levels were modified to explore the wet proton transfer and the dry charge transfer mechanism using [M+H]+ and [M+*]+ ion peak ratios, respectively. Elution times and APCI ion mass spectra profiles of UOA metabolites of interest were identified from full scan mode in preparation for MRM mode analysis. Exploration into the wet and dry mode settings of the APCI source determined that the former induced via methanol had greater peak areas and signal-to-noise ratios. Suitable MRMs were determined for clinically relevant organic acids from which a quantitative assay was developed for methyl malonic acid and several other compounds. The Waters’ Xevo TQ-S micro with Agilent 7890 GC demonstrated promising GC-APCI-MS detection of urine organic acids. With clear avenues for future work, the APCI technique hints at great benefits for biochemical genetic laboratories.

Degree

thesis:*
Department dc:contributor.department
Medical Sciences
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ganepola, Devanjith
Advisor dc:contributor.advisor
  • Potter, Murray

Subjects

dc:subject × 10

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ganepola, Devanjith. Application of Atmospheric Pressure Chemical Ionization Gas Chromatography in Urine Organic Acid Analysis. 2022. http://hdl.handle.net/11375/28058