Back to search

McMaster University

Impact of Transcatheter Aortic Valve Replacement on Coronary Hemodynamics using Clinical Measurements and an Image-Based Patient-Specific Lumped Parameter Model

Abstract

dc:description.abstract

Cardiovascular disease, including coronary artery disease and aortic valve stenosis, impacts tens of millions of people annually and carries a massive global economic burden. Advances in medical imaging, hardware and software are leading to an increased interest in the field of cardiovascular computational modelling to help combat the devastating impact of cardiovascular disease. Lumped parameter modelling (a branch of computational modelling) holds the potential of aiding in the early diagnosis of these diseases, assisting clinicians in determining personalized and optimal treatments and offering a unique in-silico setting to study cardiac and circulatory diseases due to its rapid computation time, ease of automation and relative simplicity. In this thesis, cardiovascular lumped parameter modelling is presented in detail and a patient-specific framework capable of simulating blood flow waveforms and hemodynamic data in the heart and coronary arteries was developed. The framework used only non-invasive clinical data and images (Computed Tomography images, echocardiography data and cuff blood pressure) as inputs. The novel model was then applied to 19 patients with aortic stenosis who underwent transcatheter aortic valve replacement. The diastolic coronary flow waveforms in the left anterior descending artery, left circumflex artery and right coronary artery were validated against a previously developed patient-specific 3D fluid-structure interaction model for all 19 subjects (pre and post intervention). There were strong qualitative and quantitative agreements between the two models. After the procedure, aortic valve area and net pressure gradient across the aortic valve improved for almost all the subjects. As for the hemodynamic data, according to the model, there was substantial variability in terms of the increase or decrease post intervention. On average, left ventricle workload and maximum left ventricle pressure decreased by 4.5% and 13.0% while cardiac output, mean arterial pressure and resting heart rate increased by 9.9%, 6.9% and 1.9% respectively. There were also subject specific changes in coronary blood flow (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). All in all, a proof-of-concept cardiac and coronary lumped parameter framework was developed, validated, and applied in this thesis.

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Garber, Louis
Advisor dc:contributor.advisor
  • Motamed, Zahra

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Garber, Louis. Impact of Transcatheter Aortic Valve Replacement on Coronary Hemodynamics using Clinical Measurements and an Image-Based Patient-Specific Lumped Parameter Model. 2023. http://hdl.handle.net/11375/28259