McMaster University
Time Resolved Flourescence and Diffuse Reflectance Measurements for Lung Squamous Carcinoma Tumor Margins
Abstract
dc:description.abstractLung cancer is the leading cause of death from cancer in Canada and is typically treated with surgical resection of the tumor. To ensure good prognosis and limit metastases no cancer cells can be left behind during resection. This project uses time-resolved fluorescence and diffuse reflectance to differentiate cancerous and non-cancerous lung tissue. These differences could be used during surgical resection of tumor to ensure no positive margins are present. Using a bi-modal spectroscopy device, BEAR, optical properties were determined for 36 tumor, 36 fibrotic and 9 normal lung tissue samples. Most optical parameters showed statistically significant differences between tumor and other tissue types. Metabolic based optical parameters showed statistically significant differences between fibrotic and normal tissue while non-metabolic based parameters showed no difference. As surgical margins are likely to be between tumor and fibrotic tissue the results demonstrate success and promise for implementing this system. Future work using fresh samples would develop the system further and would be a step closer to in vivo use during surgery.
Degree
thesis:*- Department dc:contributor.department
- Medical Physics
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Costa, Sarah
- Advisor dc:contributor.advisor
-
- Farquharson, Michael
Subjects
dc:subject × 2Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/14893