McMaster University
Trace Validation of Blowdown Transients Performed in the McMaster CHF Test Facility
Abstract
dc:description.abstractModelling of intermittent dryout in vertical annular flow was done using TRAC/RELAP Advanced Computational Engine (TRACE) to validate two phase conductive and convective heat transfer, and critical flow correlations. The TRACE model is based on experiments done by Statham & Novog and include the Coriolis mass flow meter, the pre-heater and the test section. Steady state and transient experiments at margin to dryout were performed at different outlet pressures and mass fluxes to investigate the influence of initial conditions on the onset of dryout. The outlet wall temperatures, equilibrium qualities and critical heat fluxes from the TRACE model are compared to experimental results. Results show that TRACE predictions of the wall temperature, mass flow and quality are in agreement with experimental results. Furthermore, potential improvements to the model are presented.
Degree
thesis:*- Department dc:contributor.department
- Engineering Physics
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Luis Daniel Abalo Sangervasi
- Advisor dc:contributor.advisor
-
- Novog, David
Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/7668