McMaster University
Stator-Flooded Direct Cooling for High Power-Density Electric Propulsion Motors: Design, Modeling, and Optimization
Abstract
dc:description.abstractThe next generation of electrified transportation requires high-power-density electric machines. However, as their power density increases, so do their heat losses, making thermal management increasingly challenging. Consequently, conventional cooling methods, such as air cooling and indirect stator jacket cooling, are insufficient to maintain these machines within safe operating temperatures. Direct cooling, in which a dielectric coolant is brought into direct contact with the heat-generating conductors, offers an effective solution for enhancing heat dissipation. This thesis investigates a stator-flooded direct liquid cooling system for a high-speed permanent magnet synchronous machine designed for an aerospace propulsion application. The majority of the heat loss in the motor under study occurs in the stator; hence, the stator is specifically chosen for the study. Although various direct-cooling configurations have been proposed in the literature, there is no comprehensive design for stator-flooded cooling systems that simultaneously accounts for coolant distribution, pressure drop, and temperature uniformity. While steady-state thermal studies for direct stator-flooded cooling systems exist in the literature, their transient behavior is less reported. Understanding the transient thermal response determines the cooling system's ability to withstand short-term thermal overloads without exceeding component temperature limits. A three-dimensional conjugate heat transfer Computational Fluid Dynamics model, validated with experimental results, is used to investigate the machine's thermal performance, while a Taguchi-based optimization approach is used to further improve coolant distribution and reduce temperature. The proposed cooling system is found to reduce the maximum motor temperature by 80 C in comparison with a baseline stator jacket system. From the transient analysis, it is found that the high thermal inertia of the proposed cooling system allows the coolant flow rate to be reduced by up to 50 % during the peak-power phase of the duty cycle without compromising thermal safety. To enable rapid thermal prediction, a three-dimensional Lumped Parameter Thermal Network model of the proposed cooling system is developed and validated. This tool is integrated with electromagnetic finite element analysis within a multi-objective optimization framework to achieve an active motor power density of 19 kW/kg.
Degree
thesis:*- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- McMaster University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Choudhary, Dikhsita
- Advisor dc:contributor.advisor
-
- Emadi, Ali
Subjects
dc:subject × 2Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/25599