Back to search

University of Missouri--Columbia

Effects of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs

Abstract

dc:description.abstract

Background: The current recommendation when performing cardiac catheterization is to obtain all invasive pressure measurements prior to any administration of contrast. This recommendation is mainly based on studies performed with traditional high-osmolar calcium binding contrast media which cause significant hemodynamic alterations such as peripheral arterial vasodilation, myocardial dysfunction, and osmotic diuresis upon administration. Updated recommendations have not been made for non-ionic contrast media which have fewer hemodynamic effects. Performing invasive pressure measurements prior to ventriculography adds additional fluoroscopy and anesthesia time, increasing both client cost and patient morbidity and mortality, as well as increasing radiation exposure to the operators. Hypothesis/Objectives: The objective was to evaluate effects of iohexol on invasive pressure assessment in dogs undergoing patent ductus arteriosus (PDA) occlusion or balloon valvuloplasty (BVP) for pulmonic stenosis (PS). We hypothesized there would not be a statistically significant difference in invasive pressure measurements obtained pre- versus post-contrast media administration in dogs undergoing routine interventional procedures, namely PDA occlusion and BVP for valvular PS. Animals: Client owned dogs (N= 30) undergoing either PDA occlusion (N=15) or BVP (N=15). Methods: Prospective observational study. Invasive pressures for PDA (main pulmonary artery (MPA) and aorta) and PS dogs (right ventricle and MPA) were obtained. Heart rate and direct peripheral blood pressure (BP) were recorded simultaneously. Pressures acquired prior to contrast injection (t0), 60-90 seconds post injection (t1), and 5 minutes post injection (t2). The mean pressure difference between time points was calculated, including peak-to-peak gradient (P2P) for PS dogs. Results: There was a significant mean difference for the following: PDA group: diastolic and mean arterial pressure in the aorta between t1-t0 (p =0.019, 0.003) and diastolic BP between t2-t0 (p=0.020); in the PS group: MPA systolic BP between t1-t0 (p=0.02). There were wide 95 percent tolerance limits for most measurements, including P2P change between t1-0 and t2-0 for dogs undergoing BVP. Conclusions and clinical importance: Although mean pressure change was generally not statistically significant, tolerance intervals suggest large changes can occur in some animals. Wide 95 percent tolerance limits for P2P could lead to misinterpretation of surgical success intra-operatively. Ideally, invasive pressure measurements should be obtained prior to contrast administration if the pressures being obtained will be utilized to make intraoperative surgical decisions.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biomedical Sciences
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Saavedra, Alix
Advisor dc:contributor.advisor
  • Wiggen, Kelly E.

Rights

Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Saavedra, Alix. Effects of non-ionic contrast media on invasive pressure measurements during minimally invasive occlusion of patent ductus arteriosus and balloon valvuloplasty for valvular pulmonic stenosis in dogs. Masters thesis, University of Missouri--Columbia, 2025. https://doi.org/10.32469/10355/109768