Novel techniques towards improving helical tomotherapy delivery and quality assurance

Abstract

dc:description.abstract

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] TomoTherapy (TomoTherapy, Inc., Madison, WI), an Image-Guided Intensity Modulated Radiation Therapy (IG-IMRT) modality, has been used to treat a variety of cancer sites. While radiation therapy, a rapidly expanding field, has increased in accuracy and provided patients with highly tailored radiation treatments, it has also increased in delivery complexity which can be potentially harmful to patients. We evaluated techniques to improve Tomotherapy patient safety and treatment workflow. Exit detector data was collected during delivered treatments with Tomotherapy's the on-board image detector. The exit detector data was used to reconstructed delivered dose distributions which gave a more accurate representation of the delivered treatments. However, this process requires additional time in the clinical workflow. To make up time, Dynamic delivery techniques, which implement dynamic jaw widths and varied couch speeds, were introduced and reported a decrease delivery times while keeping the integrity of the treatment plans. Different techniques to improve treatment delivery have been studied and the feasibility of using exit detector data for quality assurance has been explored. The results have suggested that utilizing the tools investigated in this dissertation have the potential to improve the TomoTherapy treatment process as a whole.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Nuclear engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rodriguez, Vivian
Advisors dc:contributor.advisor
  • Ghosh, Tushar K., Dr.
  • Goddu, Sreekrishna M.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Access to files is limited to the University of Missouri--Columbia with SSO login.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
OCLC
872569323

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rodriguez, Vivian. Novel techniques towards improving helical tomotherapy delivery and quality assurance. Doctoral thesis, University of Missouri--Columbia, 2012. https://doi.org/10.32469/10355/15191