Back to search

University of Missouri--Columbia

A comparison of some methods of estimating radium

Abstract

dc:description.abstract

The quantitative determination of the small amounts of radium present in the atmosphere, spring waters, minerals and rocks involves two steps: (1) The quantitative separation of the radium emanation in a known weight of the sample and (2) measurement of the ionization current produced by the emanation in a calibrated electroscope. Granting that we have accurate methods of separating radium emanation, the other problem of measuring the ionization of current and the calibration of the electroscopes for quantitative work must be given careful study, because the results ultimately depend upon the calibration constants of the electroscopes used. In the estimation of radium, the electroscope corresponds to the weights and analytical balance in ordinary quantitative chemical analysis. An electroscope is said to be standardized or calibrated when we know the quantity of radium, (or uranium) represented by some constant of the instrument. The present investigation includes the calibration of three types of alpha ray electroscopes extensively used for the determination of small quantities of radium by the emanation method. The known quantities of the radium emanation required in these experiments were obtained, (1) from uraninite (Pitchblende) of known uranium content, and (2) from a standard radium solution. In this connection a comparative study was made of the types of apparatus employed by several investigators for the separation of the emanation and its transfer to the electroscopes, with a view of standardizing the existing methods for the calibration of electroscopes.

Degree

thesis:*
Name thesis:degree_name
M.A.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Chemistry (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
1914

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bell, Louis Albert

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • OpenAccess.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
OCLC
24607988
Dc Identifier Bibid
b23400924

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bell, Louis Albert. A comparison of some methods of estimating radium. Masters thesis, University of Missouri--Columbia, 1914. https://doi.org/10.32469/10355/16138