Back to search

University of Missouri--Columbia

Development of a novel immunoassay for simultaneous quantification of endocrine parameters

Abstract

dc:description.abstract

Since the advent of the radioimmunoassay in the 1950s, numerous immunologically-based methods have evolved for sample analysis. Although each immunological method possesses unique assets and liabilities, all share limited abilities in range of concentrations detectable and the number of analytes resolvable simultaneously; most procedures are limited to one analyte determined per replicate per sample. The objective of this study was to adapt technology evolving from the genomics "revolution" for multiplexed hormonal analysis in livestock. We sought to complete this objective using the following sequencing technologies and tools: Illumina BeadXpress, Luminex xMAP, and quantitative immuno-PCR. The Illumina BeadXpress and Luminex xMAP both share similar characteristics and each of these proprietary platforms consists of a laser spectrum analyzer and a bead-set. Each bead-set contains microscopic beads and each bead-set has unique identifying signatures. As a test of proof of concept, the surface of a bead set was conjugated to an LH antibody. Using these technologies, we were able to establish an assay for LH on the Luminex platform. We were unable to develop an analyte detection assay on the Illumina platform. The restrictive proprietary constraints of both the Luminex and Illumina platforms however, greatly limited assay flexibility. Therefore, we chose to establish an assay for LH using quantitative immuno-PCR (iPCR). Quantitative immuno-PCR exploits PCR signal amplification in combination with antibody capture and specificity. Briefly, a sandwich immunoassay format is performed with capture antibody immobilized to a PCR plate. A second detection antibody, which is conjugated to an oligonucleotide, is then added to the solution phase for binding. After a series of washes to remove the unbound oligo-antibody conjugate, the plate contents are subjected to quantitative PCR (qPCR). Detection of LH was achieved, but background binding contributed to significant interference. Subsequently, to simplify the design and demonstrate proof of concept, a biotinylated oligonucleotide was competed with unlabeled biotin in streptavidin coated polystyrene plates and then detected for oligonucleotide via qPCR. The results of this latter experiment demonstrated that the iPCR methodology could detect unlabeled biotin across three orders of magnitude.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Animal sciences (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Benavides, Elizabeth
Advisor dc:contributor.advisor
  • Keisler, Duane H.

Rights

dc:rights
Statement dc:rights
  • OpenAccess.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Benavides, Elizabeth. Development of a novel immunoassay for simultaneous quantification of endocrine parameters. Doctoral thesis, University of Missouri--Columbia, 2015. https://doi.org/10.32469/10355/47113