Back to search

University of Missouri--Columbia

CCVJ's fluorescence lifetime as a viscosity measurement tool and its possible application as a tunable picoseconds reference lifetime standard

Abstract

dc:description.abstract

9-(2-carboxy-2-cyanovinyl) julolidine (CCVJ, a molecular rotor) was shown to perform as a viscosity sensitive probe. Using steady state spectroscopy, CCVJ was shown to have decreased emission intensity as the environmental viscosity decreased. The major disadvantage of this method is errors arising from concentration inaccuracies. A potential solution to this problem is to use time resolved spectroscopy to measure the fluorescence lifetime of CCVJ as a function of its environment's viscosity (the measured fluorescent lifetime is independent of concentration). Time resolved studies revealed that CCVJ exhibits a single exponential decay [vtau] which decreases with lower viscosity. A power law model that describes the fluorescence lifetime as a function of viscosity was obtained Y=0.02022[multiply]X[logical]0.4988 where R[logical]2=0.9932. It was also found that CCVJ's characteristics make it a perfect candidate to be used as a tunable picoseconds fluorescence lifetime standard. Its fluorescence lifetime varies between 0.62-0.1 nanoseconds for viscosities between 945 -13.35 mPa[multiply]s, respectively and the single exponential decay is independent of excitation wavelength. CCVJ is commercially available and can be used without further purification. Four dyes of known lifetimes were successfully measured using CCVJ in 5 different viscosities as reference lifetime standards.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biological engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Haviv, Sasson
Advisor dc:contributor.advisor
  • Haidekker, Mark A., 1963-

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
OCLC
271011872
Dc Identifier Bibid
b65264605

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Haviv, Sasson. CCVJ's fluorescence lifetime as a viscosity measurement tool and its possible application as a tunable picoseconds reference lifetime standard. Masters thesis, University of Missouri--Columbia, 2007. https://hdl.handle.net/10355/4947