Back to search

University of Missouri--Columbia

A ratiometric fluorometer for reduced sensitivity against solvent artifacts

Abstract

dc:description.abstract

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] When measuring fluorescence emission intensity, both the dye concentration and the optical absorption properties of the solvent influence the measured intensity. As a consequence, intensity-based assays (for example quenching studies or viscosity measurements using molecular rotors) lack precision. We present a ratiometric fluorophotometer capable of determining fluorescence emission simultaneously with fluid absorption at the dye's excitation and absorption wavelengths. Using suitable models, dye turbidity, emission re-absorption and dye concentration can be determined, and the measured emission intensity corrected. Validation of the prototype showed excellent correlation of measured values with commercial fluorometer (R2=0.99) and spectrometer (R2=0.97). In addition, only instrument constants remain to link emission intensity to quantum yield, a metric which is generally hard to determine. Using the same instrument with only minor modifications, fluorescence measurement through an optical fiber is possible. This allows measurements in remote areas, very small samples, and closed fluid loops. This instrument is characterized by inexpensive design, robust technology based on light-emitting diodes, its flexibility, the reduced footprint due to the integration of two standard instruments, and its increased measurement precision.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biological engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Milich, Kacy
Advisor dc:contributor.advisor
  • Haidekker, Mark A., 1963-

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Access to files is limited to the campuses of the University of Missouri with SSO login.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
Dc Identifier Bibid
b57678613

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Milich, Kacy. A ratiometric fluorometer for reduced sensitivity against solvent artifacts. Masters thesis, University of Missouri--Columbia, 2005. https://hdl.handle.net/10355/5837