Back to search

University of Missouri--Columbia

3D imaging for brachytherapy patient and mold applicator positioning verification

Abstract

dc:description.abstract

We developed a stereo vision method for 3D imaging of HDR brachytherapy skin cancer applicator positioning and tracking with respect to patients' anatomical features. The setup consists of two high-resolution scientific scan cameras (3840 x 2748 pixels) mounted on high-precision 4D of freedom optical mounts for submillimeter and sub degree positioning. A Rando phantom was used as a surrogate for patients' skin cancer and keloid treatments using a 3D printed applicator. Stereo images were recorded and analyzed using an in-house developed LabVIEW interface to determine the relative position of the applicator with respect to skin reference markers. Oncentra treatment planning system was used to perform reference applicator positioning in X, Y and Z coordinate to evaluate the stereo system accuracy and resolution. Calibration of the system spatial resolution shows optimal performance at 1000mm from the camera imaging plane to the imaged object. Calibrated screen target measurements show that positional error in the XY-plane is less than 0.39[plus or minus]0.21mm and a discrepancy in depth measurement within 0.48[plus or minus]0.32mm. Rando phantom experiments were performed to mimic skin cancer facial treatments. Tracking several reference points at the applicator we validate an average localization precision of 0.41[plus or minus]0.32mm, 0.46[plus or minus]0.38mm, and 0.3[plus or minus]0.21mm for the X, Y, and Z coordinates respectively. Applicator misplacement was simulated to determine dosimetric errors originated by applicator positioning inaccuracies. Misalignment of applicator by 5mm caused dosimetric shift up to 2.6% for overall PTV and 6.45% in reference points in treated region. The developed 3D imaging system was validated as a high-resolution and accurate stereo vision solution capable of submillimeter pre-treatment, intra and inter-fraction applicator positioning, and repeatability. This system can be used to continuously track the intra-fraction motion of the skin applicator with respect to the patient's anatomical surface to enhance treatment accuracy, safety, and quality.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Nuclear engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pokhrel, Sagar
Advisors dc:contributor.advisor
  • Izaguirre, Enrique W.
  • Loyalka, Sudarshan K.

Rights

dc:rights
Statement dc:rights
  • OpenAccess.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10355/66740

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Pokhrel, Sagar. 3D imaging for brachytherapy patient and mold applicator positioning verification. Doctoral thesis, University of Missouri--Columbia, 2017. https://hdl.handle.net/10355/66740