Back to search

University of Missouri--Columbia

Impedance based MEMS sensor for monitoring time sensitive oocyte cryopreservation

Abstract

dc:description.abstract

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] In recent centuries, women in their 30s and 40s have represented an increasing portion of fertility patients who have had difficulties in fertilization. Those patients' problems are poor oocyte quality and other reproductive sequelae like chromosomally abnormal pregnancies, such as Down's syndrome and miscarriage. Hence, these troubles along with other reasons such as diseases, including cancer, inspire researchers to study, develop and improve oocyte cryopreservation. Oocyte cryopreservation is considered a critical technique in assisted reproductive treatments (ARTs). However, the technical difficulties connected with the unique properties of the mammalian oocyte and a lack of deep understanding of oocyte cryobiology are what is behind the need for pushing for the clinical application of oocyte cryopreservation. The definition of optimal cryopreservation protocols enormously rely on the knowledge of cell membrane permeability to water and cryoprotective agents. This paper presents an innovative technique for oocyte cryopreservation by minimizing the damage to the oocyte via feedback control of the CPA concentration during equilibration. Hence, this technique differs from the current cryopreservation protocol for human female fertility that is unreliable and subject to significant user variation. The oocyte cryopreservation is achieved by equilibrating individual oocytes with high concentrations of permeating chemicals known as cryoprotectants or CPAs. This equilibration causes two modes of damage to oocytes: mechanical damage due to osmotically driven water influx and efflux, and toxic damage due to prolonged exposure to too-high CPA concentrations. Our device allows feedback control with minimal intervention; all measurements are translated directly into voltages that can be used to inform the control system to enable processing oocytes with nearly zero user intervention. Also, a goal state is given and concentrations are changed so that the desired state is achieved and maintained.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Electrical and computer engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al Yousuf, Rafal Qasim
Advisor dc:contributor.advisor
  • Almasri, Mahmoud

Rights

dc:rights
Statement dc:rights
  • Access to files is limited to the University of Missouri--Columbia with SSO login.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Al Yousuf, Rafal Qasim. Impedance based MEMS sensor for monitoring time sensitive oocyte cryopreservation. Masters thesis, University of Missouri--Columbia, 2018. https://doi.org/10.32469/10355/69882