Back to search

University of Missouri--Columbia

Environmental effects on subsurface defect detection in concrete without solar load

Abstract

dc:description.abstract

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] This study investigated the application of infrared (IR) thermography for the detection of subsurface damage in concrete. The deterioration of concrete as a result of corrosion of embedded reinforcing steel is a widespread problem. Cracking in the concrete that develops at a subsurface level manifests as delaminations that lead to spalling. These delaminations develop due to the expansion of the reinforcing steel during corrosion processes, and as such typically occur at the level of the reinforcing steel mat. As a result, this deterioration is not observable during typical visual inspections, and nondestructive evaluation (NDE) techniques such as thermography are needed to detect this deterioration in its early stages, when mitigation and repair strategies can be effective. Thermography relies on ambient environmental conditions to induce thermal gradients in the concrete that are necessary to make subsurface features observable in a thermal image. The objective of this study was to characterize the environmental conditions that enable the detection of subsurface defects in concrete bridges, and evaluate the effects of environmental parameters such as diurnal temperature variations, humidity and wind speed. The study focused on concrete surfaces not exposed to radiant heating from the sun to develop data to support guidelines for the application of IR imaging for detecting subsurface defects in concrete. A large concrete test block was constructed with embedded Styrofoam targets at various depths to simulate the effects of a subsurface delamination in the concrete. The surface temperature variations of the block were monitored continuously over a period of three months with a thermographic camera, and recorded together with onsite weather station data.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Civil and environmental engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fenwick, Richard Graham
Advisor dc:contributor.advisor
  • Washer, Glenn A.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Access to files is limited to the campuses of the University of Missouri with SSO login.
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*
OCLC
649842908
Dc Identifier Bibid
b79531210

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation