University of Missouri--Columbia
Fetoscopic in utero tracheal occlusion as a method to reduce fetal lung hypoplasia in a sheep model of congenital diaphragmatic hernia
Abstract
dc:description.abstractCongenital diaphragmatic hernia (DH) is a potentially fatal malformation that occurs in 1/2500 human births. Pulmonary hypoplasia decreases survival rate due to compression of thoracic contents by abdominal viscera. Previous studies have shown that induction of congenital high airway obstruction syndrome (CHAOS) by fetoscopic insertion of a tracheal occlusion (TO) device in utero reduces fetal lung hypoplasia. Current methods use balloons or foam plugs with complications including pressure necrosis of the trachea, decreased type II pneumocytes, and post-natal complications due to difficulty removing the device. Here, an FDA-approved endovascular device was evaluated as an alternate means of TO in fetal lambs. In 2019 and 2021, 26 ewes and their 28 fetuses were enrolled. Ewes had a hysterotomy performed at ~80-105 d gestation to create a DH in their fetus. At ~100-125 d gestation, an attempt was made to fetoscopically place the TO device. In those fetuses where a device was placed, a follow-up fetoscopy was performed 25-30 days later to attempt to remove the device. Eleven of 28 fetuses did not complete the study. Among the 17 lambs that completed the study, 13 were born naturally and 4 by terminal Cesarean section. Median gestational age at birth for those lambs completing the study was 146 (137- 157) d. Among the 14 fetuses where a DH was created, 3 had healed. Among the 11 fetuses with a patent DH, incursion of abdominal contents into the chest was observed in 8 fetuses. Percentage of the left hemithorax occupied by abdominal contents varied and was significantly lower in those lambs that had a TO device in place at birth compared with those where a device was never placed (P = 0.021). All 7 fetuses that had a TO device in place at birth had evidence of CHAOS. Among those fetuses born with a device in place, 5 of 7 had ulceration at the sites of device contact with tracheal mucosa but evidence of regeneration was present in 4 of these cases. No microscopic changes to the tracheal cartilages were noted. The percentage of type II pneumocytes in lung tissue varied significantly (P [less than] 0.001). Fetuses with a device in place at birth had a lower percentage of type II pneumocytes than those that never had a device (P = 0.001) and those where it was removed prior to birth (P = 0.008), which did not differ significantly from each other (P = 0.264). In animals in which the device was removed at least 4 days prior to necropsy, the percentage of type II pneumocytes was positively correlated with number of days since removal (R2 = 0.95; P = 0.028). The endovascular device can be successfully used for TO and generation of CHAOS in the fetal lamb model. Premature birth was not observed in lambs that completed the study without other mitigating circumstances. The device does create tracheal lesions, but preliminary evidence suggests there is potential for healing. If the device is not removed prior to birth, type II pneumocyte development is impaired and only 1 lamb shed the device on its own. Hence, some of the same complicating factors experienced with the balloon may be experienced with this device, most importantly the need to have experienced staff to remove the device at birth if not removed beforehand. Using a device with a maximum diameter smaller than the near-term tracheal diameter of the fetus might facilitate fetal expulsion of the device in late gestation or during birth improving the utility of this device.
Degree
thesis:*- Name thesis:degree_name
- M.S.
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Biomedical Sciences (MU)
- Grantor dc:publisher
- University of Missouri--Columbia
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mammone, Renata Marie
- Advisor dc:contributor.advisor
-
- Middleton, John R.
Rights
- Language dc:language.iso
- eng, English
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/10355/96206