Back to search

University of Missouri--Columbia

Full-scale glass curtain wall systems under quasi-static loading

Abstract

dc:description.abstract

Extreme events such as blasts can cause severe damage to the structural integrity of the building. Today, glass curtain wall (CW) systems are very popular facade solutions for government, education, medical, and commercial buildings. Developments in manufactured and improvised explosive device (IED)-type weapons, however, have led to an increase in explosive incidents and explosive-related casualties in recent years. Despite their popularity, relatively little experimental research has been done in analyzing full-scale CW systems; as such, this research aims to develop blast design and retrofit recommendations for modern curtain walls by performing quasi-static vacuum chamber testing of full-scale curtain wall systems. Using a 10 ft wide x 12 ft tall x 7 ft deep vacuum chamber, quasi-static loading was applied to five full-scale glass CW specimens until failure. All five specimens were stick- built using 7-1/4" aluminum mullions and six-panels of dry glazed laminated glass. The first specimen, CW1, was non-retrofitted (meaning it was built using conventionally designed anchors and shear block connections) with LG panels composed of two 1/4" annealed glass panes and 0.06" PVB interlayer. CW2 was the same design, using tempered glass rather than annealed glass panes. CW3 was retrofitted, including steel channel inserts for the mullions, aluminum tension strap running across the transoms, aluminum perimeter bearing angles, and one 7/16" bolt at the head and sill connections for each mullion, through the mullions, anchors, and inserts; CW3 utilized the same glass as CW2. CW4 was the same, with aluminum anchors and tension strap replaced by steel. Rather than PVB interlayer, CW4 was built with 0.06" SentryGlas interlayer. CW5 was the same as CW4, using two 1/4" through-bolts at each mullion connection rather than one 7/16" bolt. Pressure, deflection, and strain data were collected for the five tests, except for CW1 in which no strain was collected. It was determined through this experimentation that using annealed glass over tempered glass led to a 6 percent decrease in energy absorption of the non-retrofitted systems. Adding the aluminum retrofits (CW3) produced 67 percent more energy absorption than the non-retrofitted CW2. Changing from aluminum retrofits to steel resulted in a 65 percent increase in energy absorption compared to CW2. By far the most successful retrofit was CW5, which led to an increase in energy absorption of 106 percent compared to CW2. These absorptions were calculated based on B3 damage limit states according to Department of Defense guidelines. Though these retrofits were able to provide promising responses to quasi-static loading, further research in dynamic loading and modeling could prove beneficial in designing for blast loads.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Civil engineering (MU)
Grantor dc:publisher
University of Missouri--Columbia
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Murphy, Camdon Lynn
Advisor dc:contributor.advisor
  • Salim, Hani

Rights

Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Missouri
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Murphy, Camdon Lynn. Full-scale glass curtain wall systems under quasi-static loading. Masters thesis, University of Missouri--Columbia, 2023. https://doi.org/10.32469/10355/98812