Back to search

Massachusetts Institute of Technology

A two-step port-reduced reduced-basis component method for time domain elastodynamic PDE with application to structural health monitoring

Abstract

dc:description.abstract

We present a two-step parameterized Model Order Reduction (pMOR) technique for elastodynamic Partial Differential Equations (PDE). pMOR techniques for parameterized time domain PDEs offer opportunities for faster solution estimation. However, due to the curse of dimensionality, basic pMOR techniques fail to provide sufficiently accurate approximation when applied for large geometric domains with multiple localized excitations. Moreover, considering the time domain PDE for the construction of the reduced basis greatly increases the computational cost of the offline stage and treatment of hyperbolic PDEs suffers from pessimistic error bounds. Therefore, within the context of linear time domain PDEs for large domains with localized sources, it is of great interest to develop a pMOR approach that provides relatively low-dimensional spaces and which guarantees sufficiently accurate approximations.

Degree

thesis:*
Name thesis:degree_name
Doctoral
Department dc:contributor.department
MechE
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bhouri, Mohamed Aziz.
Advisor dc:contributor.advisor
  • Nicolas G. Hadjiconstantinou.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
OCLC
1155112057

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Bhouri, Mohamed Aziz.. A two-step port-reduced reduced-basis component method for time domain elastodynamic PDE with application to structural health monitoring. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/125483