Back to search

Michigan State University

Design, manufacturing and testing of a wound composite axial compressor with integrated shroud

Abstract

dc:description

There are a vast number of applications in which composite axial turbomachines could prove beneficial, however, current manufacturing methods can be time or cost prohibitive. Over the past several years, a novel manufacturing process aimed at reducing costs and improving structural properties has been under development at Michigan State University. This prior work established the basic manufacturing concepts and demonstrated the feasibility of utilizing the novel wound composite impellers for a number of applications in the renewable energy sector. The features of scalability and modularity put forth by this previous work have been promising. The resulting geometries that could be produced were limited to variations of the unconventional "star" pattern design. These designs generate approximately a solid body (i.e. forced vortex) swirl distribution. This work reflects a substantial improvement of the manufacturing process for wound composite impellers, while also allowing the manufacturing of any modern 3D shaped impellers with preferred swirl distributions. This was achieved through sophistication of the mandrel (mold) design and fiber layup process. By dry winding the fiber and then utilizing a vacuum assisted resin transfer molding method for the infusion process, high quality impellers were obtained. Both front and rear stage impellers of a multistage axial compressor were manufactured thereby demonstrating the flexibility of the new manufacturing process. Additionally, shaft driven and integrated drive motor configurations were designed and demonstrated. Overlaying a laser scanned model onto the CAD model of an impeller was used to visually inspect how well the resulting blade shapes matched the original design and the preliminary data indicated good agreement. Measurements of basic geometric dimensions like shroud diameter, tip radius, hub radius at leading/trailing edges and axial chord length were within 20% agreement with their design values with most below 10% and several within 1% agreement.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Qualman, Thomas J., II
Contributors dc:contributor
  • Mueller, Norbert
  • Engeda, Abraham
  • Wright, Neil
  • Liao, Wei
  • Michigan State University

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:19665
isbn:9780438757387
isbn:0438757386
oclc:1117774824
umi:13424531
local:QualmanII_grad.msu_0128D_16582

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Qualman, Thomas J., II. Design, manufacturing and testing of a wound composite axial compressor with integrated shroud. 2018. https://doi.org/doi:10.25335/df2r-rx40