Back to search

Michigan State University

High precision mass measurement of silicon-32 and developments at the LEBIT facility

Abstract

dc:description

The mass of an atom, a fundamental property, serves as a unique identier of the nucleus like a fingerprint and represents, through the binding energy, the sum of all atomic and nuclear interactions. Precise mass values are essential in many disciplines including nuclear structure and fundamental symmetries. The highest precision mass measurements are obtained with Penning trap mass spectrometers; of those, onlythe Low Energy Beam and Ion Trap (LEBIT) facility has been able to measure rare isotopes produced by projectile fragmentation. In this work, the high precision mass measurement of unstable Si-32, dm/m = 1 x10^-8, is presented and found to deviate from the literature value by four standard deviations. The measurement is combined with the mass values for the A = 32, T = 2 quintet to provide the most stringent testof the isobaric multiplet mass equation (IMME) to date. The experimental results indicate a dramatic breakdown of the quadratic form of IMME and require a large cubic term. In addition, the masses of Si-33, P-31, P-34, and S-32 were measured, which agree with earlier experimental data.Beam purity is critical to high-precision Penning trap mass spectrometry. This dissertation documents the development of in-trap cleaning of stored ion samples based on stored waveform inverse Fourier transform (SWIFT). The technique can eliminate isobaric contaminants without the need to identify individual contaminants unlike the method used in the present work. SWIFT cleaning minimizes possible systematic errors in mass determination and will increase LEBIT's measurement effciency.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kwiatkowski, Anna A.
Contributors dc:contributor
  • Bollen, Georg
  • Lapidus, Lisa
  • Morrissey, David J.
  • Zegers, Remco G.T
  • Zelevinsky, Vladimir

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:337
isbn:9781124811246
isbn:1124811249
oclc:931849017
umi:3464677
local:Kwiatkowski_grad.msu_0128D_10543

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kwiatkowski, Anna A.. High precision mass measurement of silicon-32 and developments at the LEBIT facility. 2011. https://doi.org/doi:10.25335/nkfj-za08