Back to search

Michigan State University

Development of a resistance based biosensor utilizing conducting microfibers for microbial pathogen detection

Abstract

dc:description

<italic>Escherichia coli</italic> O157:H7 (<italic>E. coli</italic> O157:H7) is one of the U.S. military's top pathogens of interest for the development of rapid diagnostic systems. The enteric pathogen can cause severe gastroenteritis and is spread through the consumption of contaminated food and water. This is of concern to the U.S. military and warfighter because an outbreak of diarrheal disease in the field has the ability to rapidly render a large number of warfighters ineffective in performing their duties. Current field &ldquoportable&rdquo detection technologies can be cumbersome and require generous quantities of chemicals to operate. In addition, the current FDA gold standard for identification of this pathogen from food matrices takes up to 3 days to generate a confirmed positive result. The objective of this dissertation research was to develop a rapid, novel electrochemical biosensor based on the use of polypropylene microfiber membranes coated with a conductive polypyrrole and antibody functionalized for the biological capture and detection of <italic>E. coli</italic> O157:H7. In this dissertation research, an electrotextile composed of conductive polymer coated microfibers containing functional attachment sites for biorecognition elements was developed. The electrotextiles were optically and electrically assessed based on the polymerization chemicals and reaction time to determine how these factors affected the resistance of the fibers. Based on these experiments, a mathematical model was developed, optimized, and validated. Various methods of antibody immobilization and surface blocking on the fibers were also assessed. Using glutaraldehyde, pathogen specific antibodies were covalently attached to the conductive microfiber electrotextiles which were then blocked using a 5% bovine serum albumin solution. The functionalized membranes were exposed to <italic>E. coli</italic> O157:H7 cells, washed in Butterfield's phosphate buffer and added to a phosphate buffer electrolyte solution. When a voltage was applied to the system, the presence of the captured pathogen on the fiber surface resulted in an increase in resistance at the electrotextile electrode surface, indicating a positive result. It was found that the conductivity of the components of the system, other than the electrotextile fibers, was not statistically significant. Proof&ndashof&ndashconcept experiments were conducted and it was determined that the electrotextile electrode was able to differentiate between positive and negative samples using the pathogen <italic>E. coli</italic> O157:H7 cells as the target over a concentration range of 10<super>0</super> &ndash 10<super>9</super> colony forming units per milliliter (CFU/mL). The reproducibility of the sensor results was tested and it was found that the trends in the biosensor results were reproducible. By testing the significance of the biosensor response it was determined that the biosensor can successfully function as a yes / no screening system. The results show that the biosensor has an experimental lower limit of detection of 3.23 x 10<super>0</super> CFU/mL for the detection of <italic>E. coli</italic> O157:H7 in pure culture.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McGraw, Shannon Katie
Contributors dc:contributor
  • Alocilja, Evangelyn
  • Gerlach, John
  • Liao, Wei
  • Rose, Joan

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:345
isbn:9781303044274
isbn:1303044277
oclc:931731656
umi:3559399
local:McGraw_grad.msu_0128D_11931

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

McGraw, Shannon Katie. Development of a resistance based biosensor utilizing conducting microfibers for microbial pathogen detection. 2013. https://doi.org/doi:10.25335/xtak-4r11