Back to search

Michigan State University

Kinetically modeling total ion chromatograms and extracted ion profiles to identify ignitable liquids for fire debris applications

Abstract

dc:description

Identification of ignitable liquids in fire debris samples is typically conducted via comparison of total ion chromatograms (TICs) of such samples to reference collections containing chromatograms of common liquids. Due to the extent of liquid evaporation in fires, reference collections often contain TICs of ignitable liquids that have been experimentally evaporated to various levels; however, such evaporations can be time intensive. A kinetic model was developed to predict evaporation rate constants of compounds as a function of GC retention index. The model can be applied to predict chromatograms of ignitable liquids at any evaporation level, alleviating the need to perform experimental evaporations. Previous work demonstrated good predictive accuracy of the model for petroleum distillate liquids and gasoline.In this work, the kinetic model was applied to ignitable liquids of the isoparaffinic, naphthenic-paraffinic, and aromatic ASTM classes. Predicted extracted ion profiles (EIPs) were generated in addition to TICs for each liquid, and good predictive accuracy of the model was demonstrated with PPMC coefficients as high as 0.9983. Reference collections containing predicted TICs and EIPs were generated. The TICs and EIPs of single-blind samples and large-scale burn samples were compared to the reference collections; in all cases, the correct ASTM liquid class was identified. Use of the EIP reference collection for the burn samples resulted in higher correlation compared to the TIC collection due to reduced substrate interferences. Overall, this work demonstrates the utility of a kinetic model for generating predicted reference collections as a tool in the identification of ignitable liquids for fire debris applications.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Capistran, Briana Ashley
Contributors dc:contributor
  • Waddell Smith, Ruth
  • McGuffin, Victoria L.
  • Smith, Christopher E.
  • Michigan State University

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:48742
isbn:9798662569171
oclc:1201189989
umi:28031746
local:Capistran_grad.msu_0128N_17772

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Capistran, Briana Ashley. Kinetically modeling total ion chromatograms and extracted ion profiles to identify ignitable liquids for fire debris applications. 2020. https://doi.org/doi:10.25335/e08x-gp37