Back to search

Michigan State University

Performance-based approach for evaluating the fire response of prestressed concrete double T-beams

Abstract

dc:description

In recent years precast/prestressed concrete (PPC) double T-beams have gained wide popularity in numerous building applications. Since structural fire safety is a high priority, building codes generally specify fire resistance requirements. The current approach for evaluating fire resistance of structural members, including those of PPC double T-beams, through prescriptive-based methods has numerous drawbacks. The guidelines are limited in scope and restrictive in application, since they were developed based on ASTM E-119 standard fire tests. Furthermore, these guidelines are only valid for a narrow range of beams and do not fully account for realistic fire, loading or restraint scenarios. To overcome these drawbacks, a performance-based methodology is applied to evaluate the fire resistance of PPC beams under realistic fire, loading, and restraint scenarios. SAFIR, a special-purpose finite element program, was used to carry a set of numerical analyses to study the effect of various factors governing the fire resistance of PPC double T-beams. In the analysis, high temperature material properties, various load and restraint levels, and material and geometric nonlinearity were accounted for. A realistic failure criterion was also included to determine failure. Results from the analysis indicate that fire scenario, load level, and failure criterion have significant influence on the fire resistance of PPC double T-beams. The steps involved in undertaking a performance-based fire approach are outlined.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hatinger, Nickolas Robert
Contributors dc:contributor
  • Kodur, Venkatesh
  • Burgueno, Rigoberto
  • Soroushian, Parviz

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:592
isbn:9781267647658
isbn:1267647655
oclc:931883349
umi:1519451
local:Hatinger_grad.msu_0128N_11589

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Hatinger, Nickolas Robert. Performance-based approach for evaluating the fire response of prestressed concrete double T-beams. 2012. https://doi.org/doi:10.25335/fcfb-m863