Back to search

Michigan State University

Residual axial capacity of fire exposed reinforced concrete columns

Abstract

dc:description

"Fire represents one of the most severe environmental loading conditions that a structure may experience during its design lifetime. Reinforced Concrete (RC) structural members can experience some level of damage following moderate or severe fire exposure. To ensure safe future use of the structure, and to develop adequate retrofitting measures for fire damaged concrete members, it is essential to evaluate the residual capacity of RC members following fire exposure and prior to re-occupancy. A limited number of experimental studies and approaches exist today that accounts for the residual capacity of fire exposed RC columns. Therefore, experimental studies have been undertaken as part of this research to understand the post-fire behavior of RC columns exposed to realistic fire scenarios. Two full-scale normal strength concrete (NSC) columns have been cast and subjected to realistic restraint, loading and fire exposure conditions. The experimental studies conducted indicate that peak rebar temperatures can occur up to 100 minutes and 80 minutes after the end of the heating phase of a 90-minute and 120-minute fire exposure, respectively. The post fire residual capacity testing indicated that the RC columns can retain up to 34% of its real nominal capacity for a 90-minute exposure and up to 29% for a 120-minute exposure. However, much of the design capacity of columns is retained after exposure to fire. In addition to the experimental studies undertaken, a numerical model developed using the commercially available finite element (FE) software, ABAQUS, is used to predict the thermal and mechanical response of RC columns before, during and after realistic fire exposure."--Page ii.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hibner, Derek R.
Contributors dc:contributor
  • Kodur, Venkatesh K.
  • Burgueno, Rigoberto
  • Soroushian, Parvis

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language
English

Identifiers

dc:identifier.*
Identifier
etd:6802
isbn:9780355236002
isbn:0355236001
oclc:1027790610
umi:10624249
local:Hibner_grad.msu_0128N_15638

Chain of custody

source
Harvested from
Michigan State University
Base URL
d.lib.msu.edu/oai
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Hibner, Derek R.. Residual axial capacity of fire exposed reinforced concrete columns. 2017. https://doi.org/doi:10.25335/kw73-2g39