Back to search

Michigan Technological University

Experimental investigations of temperature controlled innovative annular flow-boiling of FC-72 in millimeter scale ducts – steady and enhanced pulsatile realizations

Abstract

dc:description.abstract

Steady and steady-in-the-mean shear driven annular flow-boiling is experimentally investigated in this thesis. By annular flow-regime one means separated liquid and vapor flows with the flowing liquid film staying on the boiling-surface. The goals for the steady annular flow-boiling operations are to better understand relative importance of heat-transfer mechanisms (nucleation versus convective phase-change, with convective meaning absence of nucleation) and to develop better quantitative characterizations/correlations for heat-transfer rates. The goals for the steady-in-the-mean annular investigations was to explore improved means of significantly increasing heat transfer rates - while retaining the flow-regime's annularity. The experimental investigations (with FC-72 as a working fluid) were carried out within a horizontal test-section of 50 cm length and rectangular cross-section (depth = 15 mm and height = 2 mm). Temperature controlled heating (by using reversed and controllable thermo-electric coolers) at low heat-fluxes (in the range of 0.1 – 1 W/cm2) were used. The results establish enhancements between pulsatile (steady-in-the-mean) and corresponding steady cases to be up to 110% for local heat-flux measurements (at 40 cm location) and up to 18.3% for the overall heat-flux. The new physic based decomposition of heat transfer mechanisms – between micro-scale nucleate boiling and convective boiling (assuming no nucleation) – was established by synthesizing experimental data with corresponding data obtained from a very accurate 2D CFD convective modeling (assuming no nucleation) and simulation technique from Dr. Narain’s computational team. It is found that invisible micro nucleation plays a very big role in thin liquid film (400 – 40 µm thick) annular flow-boiling – and is responsible, typically, for removing about 70 to 90% of the total heat-flux at each location. Experimental data is also used to propose superior heat-transfer coefficient correlations. For steady-in-the-mean cases, it can be concluded that to enhance the heat-flux in an efficient way, inlet liquid flow rate pulsations are best - particularly if the liquid pulsator frequency at suitably small amplitude is set close to the predominant noise frequency (found from the Fast Fourier Transform of the dynamic differential pressure measurement across the test-section) already present in the steady realization.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy in Mechanical Engineering-Engineering Mechanics (PhD)
Level thesis:degree_level
Open Access Dissertation
Discipline thesis:degree_discipline
Department of Mechanical Engineering-Engineering Mechanics

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gorgitrattanagul, Patcharapol
Committee members dc:contributor.committeemember
  • Sajjad Bigham
  • Scott Miers
  • Radheshyam Tewari
  • Scott Wagner
Contributors dc:contributor
  • Amitabh Narain

Subjects

dc:subject × 5

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Michigan Technological University
Base URL
digitalcommons.mtu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gorgitrattanagul, Patcharapol. Experimental investigations of temperature controlled innovative annular flow-boiling of FC-72 in millimeter scale ducts – steady and enhanced pulsatile realizations. Open Access Dissertation thesis, https://doi.org/10.37099/mtu.dc.etdr/504