Michigan Technological University
Studying mass and mechanical property changes during the degradation of a bioadhesive with mass tracking, rheology and magnetoelastic (ME) sensors
Abstract
dc:description.abstractIn this research, the degradable polymer 4-arm poly (ethylene glycol)-glutaric acid-dopamine (PEG-GA-DM4) was synthesized. The degradation behavior of crosslinked PEG-GA-DM4 bioadhesive was studied with mass tracking, oscillatory rheology, and magnetoelastic (ME) sensors. Changes in mechanical properties were correlated with both dry mass and wet mass changes during the degradation. The results indicate that the loss of mechanical property in the bioadhesive can take place without losing the dry mass. The mass loss profile cannot describe the degradation behavior completely. In addition to studying the degradation of PEG-GA-DM4, this research also confirms the application of ME sensors as a means to study the mechanical and degradation behavior of bioadhesive.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Biomedical Engineering (MS)
- Level thesis:degree_level
- Open Access Master's Thesis
- Discipline thesis:degree_discipline
- Department of Biomedical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhang, Zhongtian
- Committee members dc:contributor.committeemember
-
- Rupak Rajachar
- Faith A. Morrison
- Contributors dc:contributor
-
- Bruce P. Lee
- Keat Ghee Ong
Subjects
dc:subject × 8Identifiers
dc:identifier.*- Identifier
- https://digitalcommons.mtu.edu/etdr/701