Back to search

Michigan Technological University

IMPACT OF GRID-CONNECTED IBRs ON AC TRANSMISSION LINE PROTECTION

Abstract

dc:description.abstract

Integration of renewable energy in the power systems has come with both pros and cons. Although these resources are eco-friendly and sustainable, they increase the complexity of power system protection studies. These resources are called Inverter-based Resources (IBR) and the control strategies used in the inverters determine what the relays see. These controls usually limit the maximum current to 1.1-1.5 pu. Moreover, the controls convert the three-phase current into dq0 domain, making the phase currents indistinguishable during a fault. Conventional relay protection schemes, such as distance protection, malfunctions due to these adversities. More advanced protection schemes, such as line differential protection, are required in these situations. Two SEL-411L relays have been used to implement an array of line differential protection tests. One of the lines (L89) in IEEE 9-bus system is the protected line in all the tests. Relay settings have been developed for each relay and a doble F6150SV power system simulator has been used to playback relay event files (COMTRADE) in the relays. An SEL-2488 Satellite Synchronized Network Clock has been used for time synchronization during the tests. An SEL-2730M Manage 24-Port Ethernet Switch has been used to connect all the test equipment to the same ethernet network. Although the line differential protection scheme performs much better than the distance protection scheme with IBR integration, there are certain challenges of implementing this scheme as well, which have been discussed in the section Recommendation for Future Work.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Electrical and Computer Engineering (MS)
Level thesis:degree_level
Campus Access Master's Thesis
Discipline thesis:degree_discipline
Department of Electrical and Computer Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gupta, Subhradeep
Committee members dc:contributor.committeemember
  • Flavio B. Costa
  • Leonard J. Bohmann
Contributors dc:contributor
  • Bruce A. Mork

Subjects

dc:subject × 6

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Michigan Technological University
Base URL
digitalcommons.mtu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gupta, Subhradeep. IMPACT OF GRID-CONNECTED IBRs ON AC TRANSMISSION LINE PROTECTION. Campus Access Master's Thesis thesis, https://doi.org/10.37099/mtu.dc.etdr/1590