Back to search

Nanyang Technological University

Evaluation of deformable image registration for contour propagation and dose accumulation in adaptive radiotherapy for prostate cancer

Abstract

dc:description.abstract

Adaptive radiotherapy (ART) is a process whereby treatment plans are modified according to the latest patient anatomy, to ensure that the target coverage and dose sparing of organs at risk (OARs) are not compromised. Image registration, a technique to transform one image to another, plays an important role in ART. Due to the flexible nature of human tissues, deformable image registration (DIR) which offers the greatest degree of freedom has emerged as the most used method to transform patients’ images, including computed tomography (CT) and cone-beam CT scans. Some common applications of DIR in ART include synthetic CT generation, contour propagation and dose accumulation. For a reliable clinical translation of the DIR results, quality assurance (QA) must be performed to verify the registration accuracy. There are two types of metrics available for DIR QA: image-based metrics and deformation vector field (DVF)-based metrics. Image-based metrics comprise contour-based metrics and landmark technique. While contour-based metrics have been widely studied and well established for DIR QA, this type of metrics require manual delineation of contours by radiation oncologists, rendering it time-consuming and subject to inter- or even intra-observer variability. In addition, several studies have suggested that contour-based metrics do not reflect the registration accuracy of regions within the contours, while landmark technique proves to be superior in this context. Meanwhile, DVF-based metrics offers the advantage of being readily available after registration, thus having the potential to expedite the DIR QA process. This thesis mainly addressed the DIR QA paradigm for prostate cancer patients in two aspects, contour propagation and dose accumulation. By quantifying and correlating the different types of metrics, we not only aimed to evaluate various DIR algorithms, but also to provide a linkage between these metrics, with the ultimate goal of speeding up the QA process and paving the way for a more robust QA system. All the projects discussed in this thesis focused on three major organs in prostate RT, including prostate (target), bladder and rectum (OARs). The first part of the thesis dealt with the DIR application in contour propagation. A novel DVF-based metric, named normalised projection, was introduced. Along with normalised projection, inverse consistency error and Jacobian determinant were also studied. Pearson correlation tests were conducted between these three DVF-based metrics and two contour-based metrics, i.e., Dice similarity coefficient (DSC) and Hausdorff distance (HD). Subsequently, machine learning (ML) models were trained to predict DSC using DVF-based metrics. The models developed were linear regression (LR), Nu Support Vector Regression (NuSVR) and Random Forest Regressor (RFR). The second part of the thesis investigated the dose accumulation application. A deformable anthropomorphic pelvis phantom was fabricated via 3D printing, and implanted with markers. These markers provided the ground truth for measuring voxel mapping accuracy, through quantification of target registration error (TRE). Four DIR software – RayStation v10B, Velocity v4.1, Slicer, and Plastimatch – were analysed by computing the mean TRE and examining its correlation with DSC. The normalised projection metric exhibited moderately positive and negative correlations with DSC and average HD, respectively, highlighting its predictive capability for contour-based metrics. The ability of ML models to extract important features further brought out the potential of DVF-based metrics in predicting DSC. Out of the three models trained, RFR performed the best, with the average mean absolute error lower than 0.07. As for dose accumulation, the in-house built phantom enabled simulation of realistic deformation scenarios and evaluation of voxel mapping accuracy. Comparison across four DIR software showed that RayStation had the highest voxel mapping accuracy. Its mean TRE ranged between 1.48 mm and 3.06 mm, which is close to or smaller than the AAPM recommended upper tolerance limit (3 mm). SlicerElastix (an extension in Slicer) displayed a remarkably strong negative correlation between mean TRE and DSC for all the organs considered. In conclusion, this thesis demonstrated the feasibility of using DVF-based metrics to predict contour-based metrics, suggesting the potential for DVF-based metrics to streamline the DIR QA workflow for contour propagation. The design of deformable phantom with markers allowed the quantification and benchmarking of voxel mapping accuracy in terms of TRE, as well as an organ-wise correlation analysis between mean TRE and DSC. Future work could be done by making appropriate modifications to the deformable phantom, thereby enabling DIR validation for dose accumulation via dosimetric criteria at the prostate site.

Degree

thesis:*
College dc:contributor.school
School of Physical and Mathematical Sciences
Grantor dc:publisher
Nanyang Technological University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wong, Yun Ming
Advisor dc:contributor.supervisor
  • Lew Wen Siang

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-28
Source record
OAI-PMH GetRecord
related terms
citation

Wong, Yun Ming. Evaluation of deformable image registration for contour propagation and dose accumulation in adaptive radiotherapy for prostate cancer. Nanyang Technological University, 2025. https://doi.org/10.32657/10356/199889